Integrations

Closes the loop between prediction and action.

Watsynq pushes RUL alerts directly into your existing maintenance workflow — so a bearing defect prediction becomes a work order automatically, not a dashboard notification nobody checks.

Watsynq RUL Engine IBM Maximo SAP Plant Maint. Infor EAM OSIsoft PI Emerson DeltaV OPC-UA / REST

Work order auto-creation on threshold breach.

A predictive alert that sits in a dashboard nobody checks is worthless. Watsynq creates the work order in your CMMS automatically when a threshold is crossed.

IBM Maximo

Certified REST connector

Auto-creates work orders with equipment ID mapping, RUL score, failure mode, and priority score. Supports Maximo Application Suite and Maximo 7.6.1+. Asset hierarchy and location fields populated from Watsynq equipment registry.

SAP Plant Maintenance

Webhook / BAPI interface

Creates PM notifications and maintenance orders via BAPI or RFC interface. Functional location and equipment number mapped from Watsynq configuration. Supports SAP ECC and SAP S/4HANA PM module.

Infor EAM

REST API

Pushes to Infor EAM Work Request API on alert threshold breach. Equipment ID, asset class, and criticality fields mapped during onboarding. Supports Infor EAM Cloud and on-premise 11.x+.

UpKeep

Webhook

Webhook integration creates work requests in UpKeep with RUL estimate, failure mode, and recommended action text. Suitable for mid-market plants running UpKeep alongside heavy-industry legacy equipment.

Pull existing process data to enrich RUL context.

Watsynq can pull existing process historian data — motor load current, ambient temperature, run hours — to give the fusion model additional context rather than treating those signals as separate streams.

This is particularly valuable for equipment running variable load profiles, where the same acoustic signature means something different at 40% load vs. 90% load.

OSIsoft PI

Motor load current
Run hours
Ambient temp

Context enrichment

Load normalisation
Cycle counting
Temp correction

Watsynq

Physics model
Better RUL CI
Fewer false alarms
Emerson DeltaV — process variable pull via OPC-UA adapter
Generic OPC-UA — any OPC-UA server with browse-read access

Any system with a REST endpoint.

If your CMMS isn't on the list above, the REST API and webhook handles it. Authentication via Bearer token. Rate limit 1,000 req/hr. OpenAPI 3.1 spec available on request.

  • Bearer token authentication — OAuth 2.0 client credentials flow
  • Webhook payload on every RUL update or threshold breach
  • OpenAPI 3.1 spec available — wire up any HTTP client in minutes
alert_event.json POST /webhook
{
  "event": "rul_alert",
  "equipment_id": "KILN-FAN-3-IB",
  "rul_days": 38,
  "confidence_interval": {
    "lower": 29,
    "upper": 49,
    "level": "0.95"
  },
  "failure_mode": "inner_race_defect",
  "defect_stage": 2,
  "contributing_signals": {
    "acoustic_emission": 0.62,
    "thermal_drift": 0.28,
    "oil_particle": 0.10
  },
  "timestamp": "2026-06-25T07:14:00Z"
}

Need a custom integration?

We connect to any system with a REST endpoint or OPC-UA feed. Tell us your CMMS version and we will confirm compatibility before the pilot starts — not after.

Confirm your integration Request OpenAPI spec